Shihlin

Product (Shilin) Specifications
S-P40T
S-P40T
S-P40T(S)

  • Magnetic contactor: non-reversing/reversing: S-P40T (S)/S-2xP40T (S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P40T (S)/MSO-2xP40T (S)
  • Enclosure: non-reversing/reversing: MS-P40T (S)/MS-2xP40T (S)
  • Enclosure with Push Button: non-reversing: MS-P40T PB (S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kW/HP/A: 11/15/44
  • 380~440V-kW/HP/A: 22/30/40

Contacts

  • non-reversing: 2a2b
  • reversing: 2×2a2b

Accessories

  • Mechanical Interlock: MPU-11
  • Surge Absorber

Auxiliary: [S] -with terminal cover

S-P30T S-P30T(S)

  • Magnetic contactor: non-reversing/reversing: S-P30T (S)/S-2xP30T (S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P30T (S)/MSO-2xP30T (S)
  • Enclosure: non-reversing/reversing: MS-P30T (S)/MS-2xP30T (S)
  • Enclosure with Push Button: non-reversing: MS-P30T PB(S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kW/HP/A: 7.5/10/30
  • 380~440V-kW/HP/A: 15/20/27

Contacts

  • non-reversing: 2a2b
  • reversing: 2×2a2b

Accessories

  • Mechanical Interlock: MPU-11
  • Surge Absorber

Auxiliary: [S]- with terminal cover

S-P15
S-P15
S-P15(S)

  • Magnetic contactor: non-reversing/reversing:S-P15(S)/S-2xP15(S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P15(S)/MSO-2xP15(S)
  • Enclosure: non-reversing/reversing: MS-P15(S)/MS-2xP15(S)
  • Enclosure with Push Button: non-reversing: MS-P15PB(S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kW/HP/A: 3.7/5/16
  • 380~440V-kW/HP/A: 5.5/7.5/12

Contacts

  • non-reversing: 1a
  • reversing: 2×1b

Accessories

  • Mechanical Interlock: MPU-11
  • Surge Absorber

Auxiliary: [S] – with terminal cover

S-P21
S-P21
S-P21(S)

  • Magnetic contactor: non-reversing/reversing: S-P21(S)/S-2xP21(S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P21(S)/MSO-2xP21(S)
  • Enclosure: non-reversing/reversing: MS-P21(S)/MS-2xP21(S)
  • Enclosure with Push Button: non-reversing: MS-P21PB(S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kW/HP/A: 5.5/7.5/24
  • 380~440V-kW/HP/A: 11/15/21

Contacts

  • non-reversing: 1a1b
  • reversing: 2×1a1b

Accessories

  • Mechanical Interlock: MPU-21
  • Surge Absorber

Auxiliary Contacts: [S] – Terminal Cover

S-P50T
S-P50T
S-P50T(S)

  • Magnetic contactor: non-reversing/reversing: S-P50T (S)/S-2xP50T (S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P50T (S)/MSO-2xP50T (S)
  • Enclosure: non-reversing/reversing: MS-P50T (S)/MS-2xP50T (S)
  • Enclosure with Push Button: non-reversing: MS-P50T PB(S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kW/HP/A:15/20/58
  • 380~440V-kW/HP/A:30/40/52

Contacts

  • non-reversing: 2a2b
  • reversing: 2×2a2b

Accessories

  • Mechanical Interlock: MPU-11
  • Surge Absorber

Auxiliary: [S] – with terminal cover

S-P11
S-P11
S-P11(S)

  • Magnetic contactor: non-reversing/reversing: S-P11(S)/S-2xP11(S)

Magnetic Switch

  • Open Type: non-reversing/reversing: MSO-P11(S)/MSO-2xP11(S)
  • Enclosure: non-reversing/reversing: MS-P11(S)/MS-2XP11(S)
  • Enclosure with Push Button: non-reversing: MS-P11PB(S)

Rated capacity CNS AC3, 3 Phase

  • 220~240V-kw/HP/A: 3/4/12
  • 380~440V-kw/HP/A: 4/5.5/9

Contacts

  • non-reversing: 1a
  • reversing: 2×1b

Accessories

  • Mechanical Interlock: MPU-11
  • Surge Absorber